Commercial PA · Warehouses & Factories

Industrial PA.

Announcements that cut through machinery, with emergency intercom for large, noisy sites.

EQUIPMENT RACK1 × T-1S012 × T-4240DSA1 × TS-205Paging microphonePriority pagingWarehouse12 × SK-815Yard (outdoor)5 × SK-45SProduction floor6 × SK-815Workshop13 × SK-811TOffices20 × SK-503W
Ceiling speakerHorn speakerCoverage100 V speaker lineOutdoor zone
Typical layout, not to scale.

What the space needs

Louder than the machines.

Industrial sites need high output, robust hardware and simple, reliable paging across large, noisy areas.

  • Cut through the noiseHigh-output horns on high taps, aimed along the aisles.
  • Paging and shift callsCalls to one area or the whole site, and shift-change tones on a timer.
  • Built for the siteIP66 horns, explosion-proof models and industrial help points.

A typical design

A typical system.

A worked example: 5 zones and 56 speakers on a pre-amp with power amplifiers. Sized by the Skyco audio builder with at least 25% amplifier headroom.

5Zones
56Speakers
610 WSpeaker load
1200 WAmplifier capacity
SourcesPaging microphoneZone select and all-call
Mixing and amplificationMixer pre-amplifierSignal distributorPower amplifier channel per zone
100 V speaker zonesZone 1 · Warehouse12 × SK-815, 180 WZone 2 · Production floor6 × SK-815, 90 WZone 3 · Workshop13 × SK-811T, 130 WZone 4 · Offices20 × SK-503W, 60 WZone 5 · Yard (outdoor)5 × SK-45S, 150 W

Priority order: paging, then music. Paging bypasses local volume controls.

Item What it does Qty
T-1S01Pre-amplifier Mixer pre-amp, 5 mic and 3 aux inputs 1
TS-205Signal distributor 1 in, 6 stereo or 12 mono outputs 1
T-4240DSAPower amplifier 4 × 240 W Class D, 100 V, 1U 2
Paging microphonePaging Desk paging microphone, matched to the amplifier 1
SK-811TCeiling speaker 8″ two-way ceiling speaker, 40/20/10 W 13
SK-503WCeiling speaker 5″ ceiling speaker, 6/3 W 20
SK-815Horn speaker Square horn, IP66, 15/7.5 W 18
SK-45SHorn speaker Outdoor horn, 30/15/7.5/3.8 W 5

Design notes

What makes it work.

  1. Horns along the aislesMount horns high on racking ends or columns and aim them down the aisles. Racking blocks sound, so cover each aisle rather than the whole floor.
  2. Ten decibels over the machinesIf the floor runs at 85 dBA, announcements need about 95 dBA. That is horn territory, on 15 W taps or more.
  3. Hazardous areasUse explosion-proof horn speakers such as the T-720X wherever flammable gas or dust is present.
  4. Power amplifiers per areaA pre-amplifier feeding 100 V power amplifiers sized per area keeps long runs and high loads manageable.
  5. Help pointsIndustrial intercom terminals give staff a direct line to the control room from the floor and the yard.

Questions

Common questions.

How many horn speakers does a warehouse need?

As a guide, one 8″ horn covers about 250 m² of a noisy warehouse, but racking decides the layout. We cover each aisle, and the audio builder gives the starting count.

Can the PA play shift-change tones?

Yes. A timer plays tones or messages to selected zones on a schedule, and paging overrides them when needed.

Do hazardous areas need special speakers?

Yes. Areas with flammable gas or dust need certified explosion-proof speakers. We specify them with your safety officer.

Adjust it in the audio builder.

Open this design in the audio builder, change the zones and floor areas, and send it to us for a quote.